Household Electrical Load and Capacity Estimate
Estimate diversified running demand, starting peak, planning service capacity and current.
Method and formulas
This planner turns a household load list into four explicit steps. Each appliance’s running and starting watts are multiplied by quantity. The simultaneity factor reduces only the running total; starting peaks are added without diversity. Planning capacity is the larger of diversified running demand and the starting total, increased by the planning margin. It is not installation approval. Service current is I = P / V at the voltage you enter. For a 120/240 V dwelling service, enter 240 V to read the equivalent current on the 240 V basis.
P_run = Σ (running watts × quantity). P_start = Σ (starting watts × quantity). P_demand = P_run × simultaneity. P_capacity = max(P_demand, P_start) × (1 + margin). I = P_capacity / V. This is not an NEC Article 220 or local-code dwelling calculation, and it does not apply a code demand-factor table.
Worked example
One 800 W running load with an 1,800 W start, quantity 1, simultaneity 1, margin 0.20 and a 240 V service. The running total is 800 W, the starting total is 1,800 W and diversified demand is 800 W. Capacity = 1,800 × 1.20 = 2,160.00 W. Current = 2,160.00 / 240 = 9.00 A.
Assumptions and limitations
- Starting peaks are treated as coincident, which is conservative.
- Simultaneity must be greater than 0 and at most 1. Margin is from 0 to 2.
- Conductor ampacity, voltage drop, breaker coordination, motor-start voltage dip and service-upgrade feasibility are not evaluated.
FAQ
Is simultaneity the same as a demand factor?
No. Simultaneity here only scales the running-watt total you entered. The demand-factor calculator uses maximum coincident demand divided by connected load. Do not mix the two ratios.
Why is starting power not diversified?
The planner treats the starting peaks you entered as able to overlap. If appliances cannot start together, reduce those starting watts in the list instead of expecting the tool to guess a sequence.
Can I size the service or a breaker from this result?
No. It is a capacity screen. Conductors, protection and code compliance need a separate review by a qualified person.
Related tools
Source records
PowerEngineerLab calculation model (SRC-BACKLOG-010)
Institution: PowerEngineerLab
Section: Diversified demand and service-current planning estimate. Not a wiring-code article. No external URL is stored.
URL on the calculation record: Not recorded
Verification date: Not recorded
Status: verified (record flag, not an external certification)